info@reliant-est.com 
Hotline: +8801710-494919
Welcome to Reliant & Safety Technology Limited, “We Serve To Save”
  • Webmail Login
  • Contact Us
  • BLOG
Reliant Energy & Safety Technology Ltd
  • Home
  • About
    • Our Key Personal
    • Clients
    • Our Technology Partner
  • Products
    • Passive Fire Protection System
    • Fire Hydrant & Sprinkler System
    • Electrical System
    • Foam Suppression System
    • Gas Suppression System
    • Industrial Pump & Accessories
    • Fire Pump
    • Lift – Elevator
    • Lightning Protection System
    • PA System
    • Power & Air Conditioning System
    • Safety Equipment’s
    • Solar Power System
    • Surveillance System – CCTV
  • Our Services
    • Design & Drawing
    • Fire Safety Plan
      • Top Fire Rated Door Manufacturers in Bangladesh 2024
      • Fire Extinguisher Installation Company
      • Fire Rated Damper
      • Fire Barrier
      • Fire & Smoke Curtain
      • Fire Rated Chemical Solutions by Reliant
      • Fire Pumps
    • Fire Alarm & Detection System
    • Automatic Sprinkler System Installation by Reliant EST
    • Fire rated color paint door
    • Foam Suppression System
    • Gas Suppression System
    • Passive Fire Protection
    • Sub Station & Generator
    • Lift Elevator
    • CCTV Surveillance
    • Access Control System
    • Public Address System
    • Industrial Pump
    • Lightning Protection System
    • Solar System
  • Gallery
  • Blog
  • Contact
Inquiry Product

Inquiry Products!

We are ready to answer right now! Sign up for a free consultation.
I consent to the processing of personal data and agree with the user agreement and privacy policy
Menu
Reliant Energy & Safety Technology Ltd
Best Fire Heat Detector
Click to enlarge
HomeFire Alarm & Detection System Best Fire Heat Detector in BD-Reliant
Previous product
What Are the Advantages of a Smoke Detector?
Smoke Detector
Back to products
Next product
Manual Call Point

Best Fire Heat Detector in BD-Reliant

Compare
Add to wishlist
Category: Fire Alarm & Detection System Tags: Best Fire Heat Detector, Fire heat detector, heat detector, smoke detector
Share
  • Description
  • Reviews (0)
  • Shipping & Delivery
Description

A Fire Heat Detector is a critical component of any fire safety system, designed to detect a rapid increase in temperature caused by fire, which activates an alarm. Unlike smoke detectors, heat detectors respond to changes in ambient heat, making them ideal for environments where smoke detectors may generate false alarms, such as kitchens, garages, and industrial areas.

How Fire Heat Detectors Work

Fire heat detectors operate by monitoring temperature changes. There are two primary types of heat detectors:

  1. Fixed Temperature Detectors – These activate when a specific temperature threshold is exceeded, typically set around 135°F (57°C).
  2. Rate-of-Rise Detectors – These are more sensitive, triggering when the temperature rises rapidly within a short period, even if it hasn’t reached the fixed threshold.

Why You Need a Fire Heat Detector

  • False Alarm Reduction: Ideal for areas where dust, smoke, or fumes are present, such as kitchens or garages.
  • Early Detection in High-Risk Areas: They provide an additional layer of safety, especially in high-temperature environments like factories or warehouses.
  • Cost-Effective Safety: Fire heat detectors are affordable yet efficient in protecting property and lives.

Types of Fire Heat Detectors Available at Reliant

At Reliant, the leading fire safety provider in Bangladesh, we offer a range of fire heat detectors tailored to meet the needs of various industries:

  • Conventional Heat Detectors: For residential and small commercial properties.
  • Addressable Heat Detectors: Ideal for large-scale facilities, allowing for pinpoint accuracy in identifying the exact location of a fire.

Why Choose Reliant for Fire Heat Detectors?

Reliant, Bangladesh’s best fire safety company, prides itself on offering reliable, cutting-edge fire detection solutions. With a strong emphasis on quality and compliance with global standards, we ensure that our fire heat detectors are both durable and highly effective.

By investing in fire heat detectors from Reliant, you safeguard your property with top-tier technology that offers quick, accurate detection and minimizes damage risk.

Benefits of Installing Fire Heat Detectors:

  • Enhanced Safety: Rapid response ensures quicker fire suppression.
  • Compliance: Adheres to Bangladesh’s fire safety regulations.
  • Minimal Maintenance: Low-maintenance devices requiring occasional checks and calibration.

Installation Process for Fire Heat Detectors

Installing a Fire Heat Detector is a straightforward yet crucial process to ensure the proper functioning of your fire safety system. Below is a step-by-step guide for safe and effective installation:

1. Identify the Right Locations

  • Install heat detectors in areas where smoke alarms may trigger false alarms, such as kitchens, garages, attics, or boiler rooms.
  • Avoid installing them in extremely dusty, dirty, or excessively hot locations unless the detector is specifically designed for those environments.
  • Ensure that heat detectors are placed on the ceiling, as heat rises and this maximizes their detection efficiency. The detector should be at least 4 inches away from any walls.

2. Ensure Correct Wiring

  • For wired heat detectors, ensure proper electrical wiring. This is crucial for conventional or addressable systems.
  • If using a wireless heat detector, ensure it communicates effectively with the central alarm panel.

3. Mounting the Detector

  • Use the manufacturer’s mounting kit, which usually includes screws and brackets.
  • Carefully secure the detector to the ceiling. Make sure it is tightly fastened to avoid any movement that may affect performance.

4. Connect to the Fire Alarm System

  • Link the heat detector to your existing fire alarm control panel.
  • In an addressable system, assign each detector a unique address for easy identification in case of an alarm.

5. Test the Detector

  • After installation, test the detector by simulating an increase in temperature.
  • For fixed temperature detectors, use a heat gun to raise the temperature gradually and ensure the alarm triggers.
  • For rate-of-rise detectors, simulate a rapid increase in heat to verify responsiveness.

6. Follow Local Fire Safety Codes

  • Ensure your installation complies with local fire safety regulations and standards.
  • Work with certified fire safety professionals, like Reliant, to guarantee that your installation is safe and code-compliant.

 

Maintenance Process for Fire Heat Detectors

Proper maintenance ensures that your fire heat detector operates at peak performance. Here are key steps to follow:

1. Regular Testing

  • Test the heat detectors monthly to ensure they are functioning correctly.
  • Use a heat-testing tool to simulate a fire scenario, ensuring the detector triggers the fire alarm.
  • For wireless systems, check the signal between the detector and control panel.

2. Clean the Detector

  • Quarterly clean the detectors to remove dust, debris, and cobwebs that may interfere with their operation.
  • Use a soft brush or vacuum cleaner attachment to clean the detector without damaging any sensitive components.

3. Inspect the Wiring

  • Annually, inspect the wiring for any signs of wear, corrosion, or damage. This is crucial for wired detectors to prevent false alarms or system failures.

4. Battery Replacement

  • For battery-operated or wireless detectors, check the battery status every 6 months and replace the batteries as needed. 
  • Keep spare batteries on hand, especially in commercial settings where downtime can be costly.

5. Professional Servicing

  • Have a professional technician inspect and service the detectors annually. This ensures all components, including sensors and wiring, are in optimal condition.
  • At Reliant, our expert team offers comprehensive maintenance packages for all types of fire heat detectors.

6. Replace Old Detectors

  • The typical lifespan of a fire heat detector is between 8 to 10 years. After this period, consider replacing them with newer models to maintain high levels of safety.

 

Why Choose Reliant for Installation and Maintenance?

Reliant is committed to providing the highest level of service in fire safety. From the precise installation of fire heat detectors to ongoing maintenance, our certified technicians ensure that your system is always functioning at peak performance. Regular checks and timely updates help prevent false alarms and ensure quick responses in the event of a fire.

Best Fire and safety equipment companies in BD like Reliant EST are the unsung stars in a world where safety is very important. They work hard to make sure that people and businesses are ready to face any problems that come up. Because they care so much about safety, following the rules, and being reliable, they are great partners for making our safety steps stronger and protecting what’s most important.

 

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Best Fire Heat Detector in BD-Reliant” Cancel reply

Your email address will not be published. Required fields are marked *

Shipping & Delivery
wood-portfolio-placeholder
wood-gallery-placeholder-4

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.

Related products

Compare
Quick view
Add to wishlist
Read more
Close

NAC Extender / Additional Power Supply

Compare
Quick view
Add to wishlist
Read more
Close

Multi Detector

Compare
Quick view
Add to wishlist
Read more
Close

Battery

What Are the Advantages of a Smoke Detector?
Compare
Quick view
Add to wishlist
Read more
Close

Smoke Detector

Compare
Quick view
Add to wishlist
Read more
Close

Conventional Sounder / Horn

Compare
Quick view
Add to wishlist
Read more
Close

Fire Alarm Control Panel

Compare
Quick view
Add to wishlist
Read more
Close

Device Backbox

Compare
Quick view
Add to wishlist
Read more
Close

Isolator Module

Office Address
House#13, Road#01, Sector#11, Uttara Model Town, Dhaka, Bangladesh.
Phone: +8801710 494919, +8801913 146384, +8801670 468794
info@reliant-est.com, reliant.est.info@gmail.com
Web: www.reliant-est.com

Branch Office Address

Kalibari, Cantonment, Pallbai, Dhaka-1206, Bangladesh.
Phone: +8801710 494919, +8801913 146384, +8801670 468794
info@reliant-est.com
Web: www.reliant-est.com

Branch Office Address

Hill Heights, Holding: 44-531/A, Road: 02, Paharika-2, South Khulshi, Chattogram
Phone: +8801710 494919, +8801913 146384, +8801670 468794
info@reliant-est.com
Web: www.reliant-est.com

Ab Reliant

  • About Us
  • Our Products
  • Our Services
  • Our Clients
Login Info
  • Webmail Login
  • Admin Login
  • Cpanel Login
  • Contact Us
  • Latest News
  • Facebook
  • LinkedIn
  • Instagram
All Rights Reserved Reliant Energy & Safety Technology Ltd | Developed By Bishal IT
Secured Website
  • Home
  • About
    • Our Key Personal
    • Clients
    • Our Technology Partner
  • Products
    • Passive Fire Protection System
    • Fire Hydrant & Sprinkler System
    • Electrical System
    • Foam Suppression System
    • Gas Suppression System
    • Industrial Pump & Accessories
    • Fire Pump
    • Lift – Elevator
    • Lightning Protection System
    • PA System
    • Power & Air Conditioning System
    • Safety Equipment’s
    • Solar Power System
    • Surveillance System – CCTV
  • Our Services
    • Design & Drawing
    • Fire Safety Plan
      • Top Fire Rated Door Manufacturers in Bangladesh 2024
      • Fire Extinguisher Installation Company
      • Fire Rated Damper
      • Fire Barrier
      • Fire & Smoke Curtain
      • Fire Rated Chemical Solutions by Reliant
      • Fire Pumps
    • Fire Alarm & Detection System
    • Automatic Sprinkler System Installation by Reliant EST
    • Fire rated color paint door
    • Foam Suppression System
    • Gas Suppression System
    • Passive Fire Protection
    • Sub Station & Generator
    • Lift Elevator
    • CCTV Surveillance
    • Access Control System
    • Public Address System
    • Industrial Pump
    • Lightning Protection System
    • Solar System
  • Gallery
  • Blog
  • Contact
Start typing to see products you are looking for.